RBH access control software and controller cabinet with Lower Hutt Town Hall in the background, illustrating a comparison of RBH and Gallagher access control for commercial NZ projects.

RBH vs Gallagher Access Control: Which Platform Fits Commercial NZ Projects?

Essential Security Supplies

An RBH vs Gallagher comparison should evaluate exact proposed platforms and project workflows. Brand-level claims about security, reliability or overall superiority are not a sound specification. This NZ decision guide compares an RBH Axiom or Integra32 proposal with a Gallagher Command Centre proposal through governance, interfaces, deployment and support.

Name the platform and scope

Ask each supplier to state software edition, version, controller family, readers and licences. RBH Integra32 and Axiom proposals should be treated separately, while the Gallagher proposal should identify its Command Centre configuration and controller models. A brand name does not establish capacity or inclusion. Keep optional functions clearly separated from the base design and verify the proposed configuration against current manufacturer documentation.

Compare administration through the same tasks

Give both suppliers identical tasks: issue a staff credential, grant a temporary contractor permission, delegate a local operator and investigate a door event. Record which licences and permissions are needed. Gallagher's Command Centre material describes a broad management platform with licensable features; this does not prove every feature is included in a particular proposal. Require a demonstration of the actual edition rather than extrapolating from a product brochure.

RBH-AXA-PRO -  RBH Axiom X Professional Security Management Software
RBH-AXA-PRO - RBH Axiom X Professional Security Management Software. Genuine supplier catalogue photograph.

Test integration ownership

Specify the required data source, event and action for each integration. Examples include identity synchronisation, video callup and floor permissions. Ask both suppliers to confirm supported versions, interfaces and the organisation responsible for faults. RBH's product ecosystem and Gallagher's integration material provide starting points for assessment, not proof of a particular third-party workflow. Keep unsupported or untested connections visible in the comparison.

Use the primary technical documentation for this specification alongside the exact proposed configuration.

Evaluate site topology and continuity

Use the same site diagram and failure cases for both proposals. Check local decisions during server or network loss, pending revocations, recovery and central visibility. Confirm the proposed controllers' real interface and power limits. A central management platform does not remove local hardware constraints. Ask for the documented configuration and an approved test rather than awarding points for unqualified resilience claims.

RBH-INT32-SOFT - Integra32Software - 64/128 Doors, Includes Web and Mobile Client
RBH-INT32-SOFT - Integra32Software - 64/128 Doors, Includes Web and Mobile Client. Genuine supplier catalogue photograph.

Review migration and support in New Zealand

If existing readers or credentials are to be reused, obtain explicit compatibility advice and test a representative sample. Compare commissioning ownership, training, update planning and support escalation. Include dependencies on specialist partners and third-party services. Avoid unapproved public price comparisons. A useful lifecycle review explains what is included, what needs an additional agreement and how changes are supported.

Select against written requirements

Create a requirement matrix with demonstrated, documented, untested and unsupported states. Keep the Essential Security Supplies RBH candidates as one possible route and obtain the Gallagher design through an appropriately qualified supplier. Do not imply Essential Security Supplies stocks or supports a Gallagher configuration unless confirmed. Choose the proposal that meets the client's requirements with clear delivery ownership, rather than presenting an evidence-free brand winner.

RBH-IRC-2000 - RBH Integra32 2-Door Controller (UL Listed) includes Enclosure with 13.8VDC, 2A power supply
RBH-IRC-2000 - RBH Integra32 2-Door Controller (UL Listed) includes Enclosure with 13.8VDC, 2A power supply. Genuine supplier catalogue photograph.

Apply the design to the actual project

Use a shortlist table with named platform, software edition, proposed controllers, required licences and integration owners. RBH's official material distinguishes Integra32 and AxiomXa, and Gallagher describes Command Centre as its central security-management platform. That gives the comparison a concrete starting point. Keep current supported hardware and optional functions attached to the supplier proposal rather than transferring a feature across editions or assuming identical reader interfaces.

Then run the same project demonstration on each shortlist. Require a temporary contractor, a delegated site operator, a relevant video or lift workflow and the agreed outage case. Score demonstrated outcomes against the client's priorities and mark an untested result honestly. Ask for the migration and support boundaries in writing. The purpose is a defensible project decision, not a generic winner or a public cost comparison. The final equipment schedule should identify exactly what will be installed and who will preserve its supported configuration through future changes.

Calculate power and prove operation during outages

Make a load schedule using the manufacturer's current figures for each lock, reader, controller and accessory. Separate continuous load from momentary or motor starting load. Check what happens when several openings operate together and when batteries recharge after a mains outage. Measure voltage at the furthest device under the worst intended load, because adequate voltage at the cabinet does not prove adequate voltage at the lock. Cable resistance, protection and connection quality all affect the result.

Agree the required behaviour for mains failure, controller communication loss and loss of the management server. Test these conditions safely under the commissioning plan and record which functions remain local and which depend on a server or external service. A cached credential might remain usable while a new revocation has not yet reached the controller. Recovery therefore needs a test of restored communication and database synchronisation as well as a simple successful door opening.

Compare the documented platform scope

Platform Documented starting point Project verification needed
RBH Integra32 Client and web-browser management route described for smaller and medium organisations. Confirm current edition, supported controllers, licences and integration scope.
RBH AxiomXa Enterprise software route built around Microsoft SQL Server. Confirm the quoted Axiom edition and avoid transferring claims from other releases.
Gallagher Command Centre Central security-management platform with additional licensable functions. Confirm controller models and the included features for the actual proposal.

See RBH Integra32 documentation, RBH AxiomXa documentation and the manufacturer references below. These are platform identities, not a guarantee that every described feature is included in a quotation.

Commissioning acceptance checklist

Agree the expected result before testing. Use the installed configuration and retain evidence of each outcome, including a failure that must be corrected. The following checks supplement the exact manufacturer procedures and the approved project design.

Required check Record to retain
Compare named editions and licences against identical operator tasks. Expected behaviour, actual result, configuration tested and responsible person. Resolve an unexpected outcome before accepting this requirement.
Test the required integration and offline behaviour on the actual proposal. Expected behaviour, actual result, configuration tested and responsible person. Resolve an unexpected outcome before accepting this requirement.
Obtain written reuse, support and migration responsibilities for each shortlisted platform. Expected behaviour, actual result, configuration tested and responsible person. Resolve an unexpected outcome before accepting this requirement.

Repeat affected checks after a material equipment, software or site change. Keep the test record with the as-built schedule so the next maintainer can understand which configuration passed and which assumptions still need review.

Equipment candidates and specification checks

These are relevant active catalogue candidates for a project review, rather than a universal recommendation or a promise of immediate stock. Use the full product page and current manufacturer information to confirm the supplied variant and its role in your design.

Review the relevant Essential Security Supplies equipment range alongside the intended workflow. For further context, read our related installer guide.

Frequently asked questions

Is there a universal winner between RBH and Gallagher?

No. Compare the exact platform configuration against the client's requirements and demonstrated workflows.

Are all Command Centre features included automatically?

No. Verify the proposal's included and additional licensable functions.

Can the Essential Security Supplies product links establish a Gallagher supply arrangement?

No. They identify RBH candidates; Gallagher supply and support must be separately confirmed.

Primary references and technical scope

Use the primary manufacturer or technical reference for the claims it covers. General design guidance does not replace the selected product's installation manual. Confirm current firmware, model variants and the approved project requirements before ordering or commissioning.

Get specification help from Essential Security Supplies

Send your site layout, equipment schedule, intended workflow and any existing model details to Essential Security Supplies for specification help and a project quotation. Identify the functions that must be demonstrated and the interfaces owned by other contractors. Our enquiry route supports a documented equipment review without publishing prices or assuming unverified compatibility.

Need Advice on Security Equipment?

Discuss product suitability, specifications and project requirements with Essential Security Supplies.

Enquire About Security Equipment